The TRCTSCTLR characteristics are:
Controls the insertion of global timestamps in the trace stream.
External register TRCTSCTLR bits [31:0] are architecturally mapped to AArch64 System register TRCTSCTLR[31:0].
This register is present only when FEAT_ETE is implemented, FEAT_TRC_EXT is implemented, and TRCIDR0.TSSIZE != 0b00000. Otherwise, direct accesses to TRCTSCTLR are RES0.
TRCTSCTLR is a 32-bit register.
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RES0 | EVENT_TYPE | RES0 | EVENT_SEL |
Reserved, RES0.
Chooses the type of Resource Selector.
EVENT_TYPE | Meaning |
---|---|
0b0 | A single Resource Selector. TRCTSCTLR.EVENT.SEL[4:0] selects the single Resource Selector, from 0-31, used to activate the resource event. |
0b1 | A Boolean-combined pair of Resource Selectors. TRCTSCTLR.EVENT.SEL[3:0] selects the Resource Selector pair, from 0-15, that has a Boolean function that is applied to it whose output is used to activate the resource event. TRCTSCTLR.EVENT.SEL[4] is RES0. |
The reset behavior of this field is:
Reserved, RES0.
Reserved, RES0.
Defines the selected Resource Selector or pair of Resource Selectors. TRCTSCTLR.EVENT.TYPE controls whether TRCTSCTLR.EVENT.SEL is the index of a single Resource Selector, or the index of a pair of Resource Selectors.
If an unimplemented Resource Selector is selected using this field, the behavior of the resource event is UNPREDICTABLE, and the resource event might fire or might not fire when the resources are not in the Paused state.
If an unimplemented Resource Selector is selected using this field, the value returned on a direct read of this field is UNKNOWN.
Selecting Resource Selector pair 0 using this field is UNPREDICTABLE, and the resource event might fire or might not fire when the resources are not in the Paused state.
The reset behavior of this field is:
Reserved, RES0.
Must be programmed if TRCCONFIGR.TS == 1.
Writes are CONSTRAINED UNPREDICTABLE if the trace unit is not in the Idle state.
Component | Offset | Instance |
---|---|---|
ETE | 0x030 | TRCTSCTLR |
Accessible as follows:
15/12/2024 22:27; 5e0a212688c6bd7aee92394b6f5e491b4d0fee1d